I IFA lnstitut fi.ir Arbeitsschutz der Deutschen Gesetzlichen Unfatlversicherung Priif- und Zertifizierungsstel{e imi}6UVTest certificate no.fFA 1205024 dated 2012-07-06 Translation DGUV TestCertificate Name and address of the holder of thecertificate: (customer): Name and address of the Manufacturer: Product designation: Type: Intended purpose: Testing based on: Test report: Remarks/ specific aspect: DustcontrolGmbH SiedlerstraBe 2 D -7 1126 Giiufelden-N ebri nqen DustcontrolAB Kumla GArdsviig 14 S-14563 Norsborg Vacuum Cleaner DC3800 H Turbo Ex Picking up of dry, hazardous to health combustible andnotelectrically conductive dusts of dust class H in explosive atmospheres specified as zone22. EN60335-1 (2002) + A'1 '1 + A1 + A12 + A2 + A13 + A14 EN60335-2-69 (2009) DIN EN60335-2-69 Annex M and CC(11l05) 1111829 from 201 1-05-04, Intertek Semko AB - Kista Stockholm 20112197711120 from2012-07-06, IFA - Sankt Augustin Vacuum cleaners areintended for picking up deposited dusts. Theuseof vacuum cleaners as dust extractors forcollecting dust emissions of machines does not constitute intended use. The type tested complies with thetestbasis specified above. Theholder of thecertificate is entitled to affix the DGUV Test mark shown overleaf to theproducts complying with thetype tested, including thespecification given under theheading 'remarks' Thepresent certificate including the right to affix the DGUV Test mark is valid until: 2016-03-02 Further provtsions concerning thevalidity, theextension of thevalidity andother conditions arelaid down in theRules of Procedure forTestinq andCertification of Auqust 2012. Posta! address: . 53757Sankt Augustin . Office: Alte HeerstraBe 111 . 53757 Sankt Augustin Phone +49 (0) 2241 231- 02. Fax +49 (0) 2241 231-2234. E-Mail [email protected] . www.dguv.de/ifa (Dr. PeterPaszkiewicz) PZBo8bEi. ., 1,,,.r, . 08.12 :_\,i-;ji:ii::r In any case,the German original shall prevail
Transcript
Page 1: I IFA - Dustcontrol UK Ltddustcontroluk.co.uk/documents/product/45-287-3.pdf · DIN EN 60335-2-69 Annex M and CC (11l05) 1111829 from 201 1-05-04, Intertek Semko AB - Kista Stockholm

I IFAlnstitut fi.ir Arbeitsschutz derDeutschen Gesetzlichen UnfatlversicherungPriif- und Zertifizierungsstel{e im i}6UVTest

certificateno. fFA 1205024dated 2012-07-06

Translation

DGUV Test Certificate

Name and address of theholder of the certificate:(customer):

Name and address of theManufacturer:

Product designation:

Type:

Intended purpose:

Testing based on:

Test report:

Remarks/specific aspect:

DustcontrolGmbHSiedlerstraBe 2D -7 1 126 Giiufelden-N ebri nqen

DustcontrolABKumla GArdsviig 14S-14563 Norsborg

Vacuum Cleaner

DC 3800 H Turbo Ex

Picking up of dry, hazardous to health combustible and not electricallyconductive dusts of dust class H in explosive atmospheres specified aszone22 .

EN 60335-1 (2002) + A'1 '1 + A1 + A12 + A2 + A13 + A14EN 60335-2-69 (2009)DIN EN 60335-2-69 Annex M and CC (11l05)

1111829 from 201 1-05-04, Intertek Semko AB - Kista Stockholm20112197711120 from2012-07-06, IFA - Sankt Augustin

Vacuum cleaners are intended for picking up deposited dusts.The use of vacuum cleaners as dust extractors for collecting dustemissions of machines does not constitute intended use.

The type tested complies with the test basis specified above.The holder of the certificate is entitled to affix the DGUV Test mark shown overleaf to the productscomplying with the type tested, including the specification given under the heading 'remarks'

The present certificate including the right to affix the DGUV Test mark is valid until: 2016-03-02

Further provtsions concerning the validity, the extension of the validity and other conditions are laiddown in the Rules of Procedure for Testinq and Certification of Auqust 2012.

Posta! address: . 53757 Sankt Augustin . Office: Alte HeerstraBe 111 . 53757 Sankt AugustinPhone +49 (0) 2241 231- 02. Fax +49 (0) 2241 231- 2234. E-Mail [email protected] . www.dguv.de/ifa

(Dr. Peter Paszkiewicz)

P Z B o 8 b E i . . , 1 , , , . r , .08.12

:_ \ , i - ; j i : i i : : r

In any case, the German original shall prevail

Page 2: I IFA - Dustcontrol UK Ltddustcontroluk.co.uk/documents/product/45-287-3.pdf · DIN EN 60335-2-69 Annex M and CC (11l05) 1111829 from 201 1-05-04, Intertek Semko AB - Kista Stockholm

Reverse side of the DGUV Test Certificate

DGUV Test mark

rFA. . . . . 1 )

t g l

1) no. of certificate

PZBOSbE08.12


Recommended