Date post: | 04-Jan-2016 |
Category: |
Documents |
Upload: | emery-waller |
View: | 67 times |
Download: | 5 times |
Analytische Chemie – Elektroanalytik & Sensorik RUHR-UNIVERSITÄT BOCHUM
1
Perspective pentru un nou biocatod de potenţial ridicat – noi proprietăţi ale
enzimelor redox imobilizate pe nanostructuri compozite de grafit
-
Wenzhi Jia, Yvonne Ackermann, Wolfgang Schuhmann, Leonard Stoica
Anal. Chem. - Elektroanalytik & Sensorik (ELAN)Universitätsstr. 150, Bochum 44780
Ruhr-University BochumGermany
Analytische Chemie – Elektroanalytik & Sensorik RUHR-UNIVERSITÄT BOCHUM
Concept of bienzymatic membrane-less biofuel cell (BFC)
laccase
cellobiose dehydrogenase (CDH) Potential [mV] vs. Ag/AgCl 3M KCl
- ++150 -41 +450 +530 Ecell = 300
ano
de
catho
de
e-
e- e-
cellobiose dehydrogenase laccase
lactose
lactoso-lactone
e-
Os
Os OsOs
OsOs
Os
Os
Os
Os
Os
loading
H2O
O2
Stoica L. et al, Fuel Cells (2009), 9 (1), 53-62
Analytische Chemie – Elektroanalytik & Sensorik RUHR-UNIVERSITÄT BOCHUM
3
Motivation for new material electrode• High catalytic coverage:
– large amount of active enzyme;
• Large active area of electrode:– using hierarchical carboneous materials two-
generations CNT‘s
• Exploring specific properties of bio-nano interactions.
Pout=E x I
[E]; A; kcat, n
E0‘
Analytische Chemie – Elektroanalytik & Sensorik RUHR-UNIVERSITÄT BOCHUM
I. Large active area electrode
4
Analytische Chemie – Elektroanalytik & Sensorik RUHR-UNIVERSITÄT BOCHUM
5
Graphite electrode surface
Analytische Chemie – Elektroanalytik & Sensorik RUHR-UNIVERSITÄT BOCHUM
6
Composite material:CNT/CMF onto carbon paper
Preparation:
N. Li, X. Chen, L. Stoica, W. Xia, J. Qian, J. Aßmann, W. Schuhmann, M. Muhler
Adv. Mater. (2007), 19, 2957-2960
Analytische Chemie – Elektroanalytik & Sensorik RUHR-UNIVERSITÄT BOCHUM
7
EIS characterisation of CNT/CMF
Properties:•Low ohmic resistance => no potential loss;
•Ratio active/geometric area=200;
•Non-restrictive diffusion of enzyme substrate.
N. Li, X. Chen, L. Stoica, W. Xia, J. Qian, J. Aßmann, W. Schuhmann, M. Muhler
Adv. Mater. (2007), 19, 2957-2960
Analytische Chemie – Elektroanalytik & Sensorik RUHR-UNIVERSITÄT BOCHUM
8
Various supports
Analytische Chemie – Elektroanalytik & Sensorik RUHR-UNIVERSITÄT BOCHUM
9
Analytische Chemie – Elektroanalytik & Sensorik RUHR-UNIVERSITÄT BOCHUM
II. Exploring specific bio-nano interactions
10
Analytische Chemie – Elektroanalytik & Sensorik RUHR-UNIVERSITÄT BOCHUM
11
250 results
HRP-CNT
Y. Yan et al., Langmuir 2005, 21, 6560-6566
...only at low potentials!!
Analytische Chemie – Elektroanalytik & Sensorik RUHR-UNIVERSITÄT BOCHUM
13
Thermodynamic potential for reduction = +750 mV
Analytische Chemie – Elektroanalytik & Sensorik RUHR-UNIVERSITÄT BOCHUM
14
Any
specific bioelectrochemistry of HRP
@ these new materials?
Analytische Chemie – Elektroanalytik & Sensorik RUHR-UNIVERSITÄT BOCHUM
15
Bioelectrochemistry of HRP-heme
-53 mV / pH unit
PHA - pyrene-hexanoic acid
Analytische Chemie – Elektroanalytik & Sensorik RUHR-UNIVERSITÄT BOCHUM
16
Bioelectrocatalytic current forH2O2 reduction at +600 mV
Analytische Chemie – Elektroanalytik & Sensorik RUHR-UNIVERSITÄT BOCHUM
17
Optimum pH
@ +400 mV vs. Ag/AgCl
Bioelectrocatalytic current forH2O2 reduction at +600 mV
PHA - pyrene-hexanoic acid
Analytische Chemie – Elektroanalytik & Sensorik RUHR-UNIVERSITÄT BOCHUM
18
Hydrodynamic voltammogram
H202 oxidation
H202 reduction
at electrode
at HRP
High potential reduction of Cmp-I/II-HRP
Analytische Chemie – Elektroanalytik & Sensorik RUHR-UNIVERSITÄT BOCHUM
19
Scheme of H2O2 involvement
H2O2
H2O HRPox
HRPred
Biocathode@ +600 mV
1e-
+1e-
W. Jia, S. Schwamborn, C. Jin, W. Xia, M. Muhler, W. Schuhmann, L. Stoica PCCP 12 (2010) 10088.
Analytische Chemie – Elektroanalytik & Sensorik RUHR-UNIVERSITÄT BOCHUM
20
H2O2 biosensor at +400 mV@ no O2 involvement
Amperometric responses of the HRP/PHA-CNTs/CF/GR biosensor were recorded by additions of H2O2 in N2-saturated PBS (pH 7.0) at +400 mV
Imax= 220 µA (~ 1.5 mM H2O2) KM= 320 µM H2O2
Analytische Chemie – Elektroanalytik & Sensorik RUHR-UNIVERSITÄT BOCHUM
21
HRP loading
Eappl=+300 mV
0 1 2 3 4 5 60
-200
-400
-600
-800I /
µA
[H2O
2] / mM
25 µg HRP
50 µg HRP
100 µg HRP
150 µg HRP
200 µg HRP
@ 1 cm-2
Analytische Chemie – Elektroanalytik & Sensorik RUHR-UNIVERSITÄT BOCHUM
22
Is „glucose based cathode“ a promising candidate?
Biocathodes based on... Eonset pHopt
Cl- inhibition
e- / O2 yield
Laccase +650 4 YES 4 e-Bilirubin oxidase +200 6-7 NO 4 e-
Glucose/HRP +600 7 NO 2 e-
Pout=E x I [E]; A; kcat, n E0‘
Analytische Chemie – Elektroanalytik & Sensorik RUHR-UNIVERSITÄT BOCHUM
23
Conclusions
3D-hierachical carbon nanostructures:– present excellent characteristics for large active area
and enhanced/”novel” bioelectrocatalysis of known redox enzymes;
Biocathode enzyme:– Yes, indeed, high potential biocathode functioning on
glucose/oxygen is feasible at in-vivo conditions (pH, Cl-)
Analytische Chemie – Elektroanalytik & Sensorik RUHR-UNIVERSITÄT BOCHUM
24
Acknowledgements go to...• EU-FP7 funds (project no. FP7-NMP-2008-SMALL-2 )
• to ELANOS
Analytische Chemie – Elektroanalytik & Sensorik RUHR-UNIVERSITÄT BOCHUM
25
for your attention!Thank you